Choosing a sauna heater: kW, Wi-Fi control and what each one needs
A sauna heater is chosen by the volume of the hot room in cubic metres, and glass makes the room behave as if it were bigger. Harvia’s rule is to add 1.2 m³ for every square metre of glass or uninsulated wall, then pick the heater whose range covers the result. Here is how to count the glass, what Wi-Fi control changes and what a bigger heater asks of your electrics.
- Use cubic metres to size the heater. The 6.8 kW Cilindro PC70 is rated for rooms of 6–10 m³ and the 9 kW PC90 for 8–14 m³.
- Glass adds volume. Add 1.2 m³ for each square metre of glass or uninsulated wall. For log walls, multiply the volume by 1.5.
- A bigger heater needs a bigger supply. Our product pages specify a dedicated 35 A circuit for the PC70 and a 40 A circuit for the PC90. A qualified electrician sizes and fits the circuit.
How are sauna heaters sized?
By the volume of the hot room. Each heater is rated for a range of room volumes in cubic metres, and you choose the one whose range covers your room once glass and bare walls are counted.
Floor area tells you how many people fit on the benches. It says nothing about how much air the heater has to warm, because a tall room holds more air than a low one with the same floor. Heater makers therefore publish a minimum and a maximum room volume for every model, and Harvia’s installation manual for the Cilindro range asks installers to check that “the output and type of the heater” suit the sauna room before anything is fixed to the wall.
The same manual explains how to judge it. In a room with panelled walls and ceiling and enough insulation behind the panels, the heater output follows the volume of the room. Then comes the correction that catches most people out: walls that hold heat badly push the requirement up.
How do you work out the volume of your hot room?
Multiply the inside length, width and height of the hot room in metres, then add the allowance for glass. The calculator in our guide to sauna size does both steps for you.
Measure inside the panelling and leave out the changing room and the porch: only the room with the heater counts. Under an arched roof, the highest point is not the height over the whole floor, so ask the maker for the hot room’s volume or work it from the roof profile. A room 2.06 m long, 1.75 m wide and 2.0 m high holds about 7.2 m³. Our article on what size sauna you need has a calculator that does it step by step, with a worked example. Compare cabin sizes in our electric sauna range before matching the heater to the room. For a log-fired option, compare the rooms in our wood-fired saunas before checking the stove manual.
The height matters more than people expect. A sauna is usually 2,100–2,300 mm high, with no more than 1,200 mm between the upper bench and the ceiling, because heat collects at the top of the room and the bench has to sit in it. Each heater also has a minimum ceiling height: 1,900 mm for the PC70 and the PC90.
Why does glass change the heater you need?
Glass, brick, tile and concrete lose heat faster than an insulated timber wall. Harvia’s manual says to add 1.2 m³ to the room volume for each square metre of such surface, and to multiply the volume by 1.5 if the walls are solid logs.
The manual puts it plainly: “Add 1,2 m³ to the volume of the sauna for each non-insulated wall square meter. For example, a 10 m³ sauna room with a glass door equals the output requirement of about a 12 m³ sauna room.” Log walls get their own rule, because the timber soaks up heat as the room warms: the volume is multiplied by 1.5.
A standard sauna door shows how quickly this adds up. The glass door on our cabins measures 1770 × 690 mm, which is about 1.2 m² of glass, so it adds roughly 1.5 m³ on its own. A room that measures 7.2 m³ with a tape measure behaves, for the heater, like a room of nearly 9 m³. The extra cubic metres account for heat lost through the glass. They add no bench space.
| Hot room | What the glass adds | Equivalent volume | Harvia PC70 (6–10 m³) | Harvia PC90 (8–14 m³) |
|---|---|---|---|---|
| The Cabin Four, 206 × 175 cm, glass door | about 1.5 m³ | about 8.5 m³ | inside the range | inside the range |
| The Cabin Six Two-Tier, 206 × 185 cm, glass partition door | about 1.5 m³ | about 9 m³ | inside the range | inside the range |
| The Cabin Four or Six with the panoramic back wall | door plus a 2100 × 1050 mm panel | about 11 m³ | above the range | inside the range |
The last row is why the pages for The Cabin Four and The Cabin Six recommend the 9 kW PC90 with the panoramic back wall. The panel is 2100 × 1050 mm of 8 mm glass with an arched top, and it lifts the equivalent volume past the PC70’s upper limit of 10 m³.
Which Harvia heater covers which room?
Find your equivalent volume in the ranges below. Where two heaters overlap, as the PC70 and PC90 do between 8 and 10 m³, either fits, and the 9 kW model reaches temperature sooner.
| Heater | Output | Room volume | Minimum ceiling height | Controls |
|---|---|---|---|---|
| Cilindro PC70 | 6.8 kW | 6–10 m³ | 1,900 mm | knobs on the heater |
| Cilindro PC70E | 6.8 kW | 6–10 m³ | 1,900 mm | separate Wi-Fi control unit |
| Cilindro PC90 | 9.0 kW | 8–14 m³ | 1,900 mm | knobs on the heater |
| Cilindro PC90E | 9.0 kW | 8–14 m³ | 1,900 mm | separate Wi-Fi control unit |
Both Harvia sauna heaters, the PC70 and the PC90, hold up to 80 kg of 5–10 cm stones, which our sauna stones guide shows how to stack. The E models heat exactly the same rooms as their siblings. What changes is where the controls live: the knobs move from the heater to a separate control unit, which lets you switch the sauna on from your phone. Pick the output first and the controls second.
Stay inside the published range at both ends. The minimum volume and the minimum ceiling height belong to the safety part of the manual, alongside the distances to walls and benches, and Harvia says the cubic volumes in its table “should be followed”. A heater well short of the room will also take a long time to bring it up to temperature, which our article on how long an outdoor sauna takes to heat up covers in detail.
What does a bigger heater ask of your supply?
Its own circuit, sized to the heater. On our pages the PC70 needs 35 A in 3 × 6 mm² cable and the PC90 40 A in 3 × 10 mm², with final sizing and protection to BS 7671 by a qualified electrician.
Moving from the PC70 to the PC90 is a step up in current as well as in kilowatts, so settle it before the electrician quotes. A new circuit is notifiable work under Part P of the Building Regulations in England, and the IET’s guide to Part P counts a room containing a sauna heater as a special location, where changes to existing circuits are notifiable too. A registered electrician can certify the work. Otherwise, building control has to be told before it starts. One more rule comes with the heater: only one electric heater may be installed in a sauna room.
Our guide to electrical requirements for an outdoor sauna goes through the supply, the cable route to the garden and the questions to ask the electrician.
Does the same rule apply to wood-burning stoves?
Yes. Wood stoves are also rated for a range of room volumes, and glass counts the same way. The stoves on our wood-fired cabins are rated for 6–12 m³ or 6–13 m³.
| Stove | Rated room volume | Stones |
|---|---|---|
| ETNA 12 SN | 6–12 m³ | up to 80 kg |
| Stoveman 13R-LS | 6–13 m³ | 90–110 kg |
| Cozy 12 O-TW | 6–13 m³ | up to 120 kg |
Sauna stoves give out heat according to how they are fired, so a stove’s manual, more than the kilowatt figure, tells you how to run it in a given room. If you are still choosing between an electric sauna and a wood-fired one, our comparison of electric and wood-fired sauna heaters sets out the everyday differences.
Quick answers about sauna heater size
Not with Harvia’s electric heaters: only one electric heater may be installed in the sauna room.
Wi-Fi changes where you use the controls. The PC70E still covers 6–10 m³, just like the PC70, while the PC90E covers the same 8–14 m³ as the PC90. Moving the control unit does not change either heater’s rating.
Check the heater’s manual for the stone load. Both the PC70 and PC90 take up to 80 kg of 5–10 cm stones. Other models have their own loads, which depend on the heater rather than the room.
Each hour switched on draws more power, but a well-matched heater reaches temperature sooner. Our running costs guide shows how to work out a session from the kW and your tariff.
What should you write down before you choose?
The length, width and height of the hot room, the area of every pane of glass, and the heater range that covers the total. Four figures settle it.
Take a tape measure to the hot room, or to the plans if the cabin is still on paper, and work the sum before anyone talks about brands. For the hot rooms of our cabins the answer lands between about 8.5 and 11 m³, which is where the PC70’s range ends and the PC90’s takes over.
See the heater options on The Cabin Three
The product page lists the heater options and their prices, the Wi-Fi version and what each one needs from your supply. An expert can check your numbers with you before you order.
What we checked for this guide
Heater ranges, heights and the glass rule come from Harvia’s manual and product pages; supply figures come from our heater pages, and the Part P rule from the IET’s guide. Checked 4 November 2026.
- 01HarviaCilindro installation and user manual
- 02HarviaCilindro PC70 product page
- 03HarviaCilindro PC90 product page
- 04IETGuide to Part P
Related guides
Written by the Waldenhaus team. We sell outdoor saunas and greenhouses and write these guides from manufacturer manuals, official guidance and our own product pages. Where your equipment manual says something different, follow the manual.